Customization: | Available |
---|---|
After-sales Service: | 24 Hours Online |
Warranty: | 10years |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Battery Type
|
Lead-acid or Li-lon
|
|
|
|
|
|||||
Battery Voltage Range (V)
|
40~60
|
|
|
|
|
|||||
Max. Charging Current (A)
|
120
|
150
|
190
|
210
|
240
|
|||||
Max. Discharging Current (A)
|
120
|
150
|
190
|
210
|
240
|
|||||
External Temperature Sensor
|
Yes
|
|
|
|
|
|||||
Charging Curve
|
3 Stages / Equalization
|
|
|
|
|
|||||
Charging Strategy for Li-Ion Battery
|
Self-adaption to BMS
|
|
|
|
|
|||||
PV String Input Data
|
|
|
|
|
|
|||||
Max. DC Input Power (W)
|
6500
|
7800
|
10400
|
13000
|
15600
|
|||||
Rated PV Input Voltage (V)
|
550 (160~800)
|
|
|
|
|
|||||
Start-up Voltage (V)
|
160
|
|
|
|
|
|||||
MPPT Voltage Range (V)
|
200-650
|
|
|
|
|
|||||
Full Load DC Voltage Range (V)
|
350-650
|
|
|
|
|
|||||
PV Input Current (A)
|
13+13
|
|
|
26+13
|
|
|||||
Max. PV ISC (A)
|
17+17
|
|
|
34+17
|
|
|||||
Number of MPPT / Strings per MPPT
|
2/1+1
|
|
|
2/2+1
|
|
|||||
AC Output Data
|
|
|
|
|
|
|||||
Rated AC Output and UPS Power (W)
|
5000
|
6000
|
8000
|
10000
|
12000
|
|||||
Max. AC Output Power (W)
|
5500
|
6600
|
8800
|
11000
|
13200
|
|||||
AC Output Rated Current (A)
|
7.6
|
9.1
|
12.1
|
15.2
|
18.2
|
|||||
Max. AC Current (A)
|
11.4
|
13.6
|
18.2
|
22.7
|
27.3
|
|||||
Max. Continuous AC Passthrough
|
45A
|
|
|
|
|
|||||
Peak Power (off grid)
|
2 time of rated power, 10 S
|
|
|
|
|
|||||
Power Factor
|
0.8 leading to 0.8 lagging
|
|
|
|
|
|||||
Output Frequency and Voltage
|
50/60Hz; 3L/N/PE 220/380, 230/400Vac
|
|
|
|
|
|||||
Grid Type
|
Three Phase
|
|
|
|
|
|||||
DC injection current (mA)
|
THD<3% (Linear load<1.5%)
|
|
|
|
|
|||||
Efficiency
|
|
|
|
|
|
|||||
Max. Efficiency
|
97.60%
|
|
|
|
|
|||||
Euro Efficiency
|
97.60%
|
|
|
|
|
|||||
MPPT Efficiency
|
97.60%
|
|
|
|
|
|||||
Protection
|
|
|
|
|
|
|||||
Integrated
|
PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor
Detection, Residual Current Monitoring Unit, Output Over Current Protection,Surge protection |
|
|
|
|
|||||
Certifications and Standards
|
|
|
|
|
|
|||||
Grid Regulation
|
CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98,VDE 0126-1-1, RD 1699, C10-11
|
|
|
|
|
|||||
Safety EMC / Standard
|
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
|
|
|
|
|
|||||
General Data
|
|
|
|
|
|
|||||
Operating Temperature Range
|
-45~60, >45 derating
|
|
|
|
|
|||||
Cooling
|
Smrat cooling
|
|
|
|
|
|||||
Noise (dB)
|
<45 dB
|
|
|
|
|
|||||
Communication with BMS
|
RS485; CAN
|
|
|
|
|
|||||
Weight (kg)
|
33.6
|
|
|
|
|
|||||
Size (mm)
|
422W x 699.3H x279D
|
|
|
|
|
|||||
Protection Degree
|
IP65
|
|
|
|
|
|||||
Installation Style
|
Wall-mounted
|
|
|
|
|
|||||
Warranty
|
5 years
|
|
|
|
|