Customization: | Available |
---|---|
After-sales Service: | 24 Hours |
Warranty: | 1year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model:HFP | 33224 | 43224 | 63248 | 83248 | 103248 | 123248 | ||||||
PV Input | ||||||||||||
Max PV input power | 5000W | 7000W | 4500W*2 | 6000W*2 | 6000W*2 | |||||||
MPPT Tracking Voltage Range | 40Vdc-450Vdc | 80Vdc-450Vdc | ||||||||||
Rated Voltage | 360Vdc | |||||||||||
Max PV Input Voltage voc (at the lowest temperature) |
500Vdc | |||||||||||
Max PV Input Current | 18A | 27A | 18A*2 | 22A*2 | 27A*2 | |||||||
MPPT Tracking Channels (Input Routed ) |
1 Routed | 2 Routed | ||||||||||
Battery& Charging |
||||||||||||
Battery Type | Lead-acid Battery/Lithium Battery Custom Battery (Charging and discharging paramcters of different types of batteriescan be set through the operation board) |
|||||||||||
Rated Battery Voltage | Lead-acid Battery/Lithium Battery Custom Battery (Charging and discharging paramcters of different types of batteriescan be set through the operation board) |
|||||||||||
Battery voltage Range | 24Vdc | 48Vdc | ||||||||||
Max PV Charging Current | 120A | 150A | 120A | 150A | 180A | 200A | ||||||
Max AC Charging Current | 80A | 100A | 80A | 100A | 120A | 140A | ||||||
Max Charging Current | 120A | 150A | 120A | 150A | 180A | 200A | ||||||
On-Grid Operation(On-Grid Output(AC)) |
||||||||||||
Rated Output Power | 3300W | 4300W | 6300W | 8300W | 10.3KW | 12.3KW | ||||||
Rated Output Voltage | 220VAC/230VAC/240VAC | |||||||||||
Grid Voltage Range | 187VAC~264VAC | |||||||||||
Rated Output Frequency | 50Hz/60Hz | |||||||||||
Frequency Range | 47Hz~52Hz(50Hz),57Hz~62Hz(60Hz) | |||||||||||
Rated Output Current | 14.5A/13.9A/13.3A | 19.5A/18.7A/17.9A | 28.6A/27.4A/26.2A | 37.7A/36.1A/34.6A | 46.7A/44.9A/42.9A | 55.9A/53.5A/51.3A | ||||||
Power Factor | >0.98(Rated Power) | |||||||||||
Off-Grid Operation(AC Input) | ||||||||||||
Rated Input voltage | 220V /230V/240V | |||||||||||
Mains input voltage range | 165VAC-280VAC/ 120VAC~280VAC(Can be set) | |||||||||||
Rated Input Frequency | 50Hz/60Hz | |||||||||||
Input Frequency Range | 45Hz~55Hz(50Hz),55Hz~65Hz(60Hz) | |||||||||||
Off-Grid Operation(AC Output) | ||||||||||||
Rated Output Power | 3300W | 4300W | 6300W | 8300W | 10.3KW | 12.3KW | ||||||
Rated Output Voltage | 220V /230V/240V | |||||||||||
Output Voltage Accuracy | ±2% | |||||||||||
Rated Input Frequency | 50Hz/60Hz | |||||||||||
Output Frequency Accuracy | ±1% | |||||||||||
Output Wave | Pure Sine Wave | |||||||||||
Hybrid Operation (Complementary Mode(AC Input)) | ||||||||||||
Rated Input voltage | 220V /230V/240V | |||||||||||
Mains input voltage range | 187VAC~264VAC | |||||||||||
Rated Input Frequency | 50Hz/60Hz | |||||||||||
Input Frequency Range | 47Hz~52Hz(50Hz),57Hz-62Hz(60Hz) | |||||||||||
Hybrid Operation (Complementary Mode(AC Output)) | ||||||||||||
Rated Output Power | 3300W | 4300W | 6300W | 8300W | 10.3KW | 12.3KW | ||||||
Rated Voltage Rated | 220VAC/230VAC/240VAC | |||||||||||
Output Current | 14.5A/13.9A/13.3A | 19.5A/18.7A/17.9A | 28.6A/27.4A/26.2A | 37.7A/36.1A/34.6A | 46.7A/44.9A/42.9A | 55.9A/53.5A/51.3A | ||||||
General parameters | ||||||||||||
Maximum Conversion Efficiency (Battery Discharge) |
94%(peak value) | |||||||||||
MPPT Tracking Efficiency | ≥99.9 | |||||||||||
Transfer Time | 10ms(Typical value) | |||||||||||
Display | LCD+LED | |||||||||||
Cooling Method | Cooling fan in intelligent control | |||||||||||
Communication | RS485/Mobile APP(WIFI Monitoring or GPRS monitoring)(Optional) | |||||||||||
Protection Degree | IP20 | |||||||||||
Installation | Wall-Mounted | |||||||||||
Protect | ||||||||||||
Battery low voltage alarm | 22VDC (default value) | 44VDC (default value) | ||||||||||
Battery low voltage protection | 21VDC (default value) | 42VDC (default value) | ||||||||||
Anti-islanding protection | ≤2S | |||||||||||
overload power protection | Automatic Protection (battery mode),Circuit Breaker or Insurance (AC mode) | |||||||||||
Inverter output short circuit protection |
Automatic Protection (battery mode),Circuit Breaker or Insurance (AC mode) | |||||||||||
Temperature protection | >90(Turn off inverter and charging) | |||||||||||
Environment | ||||||||||||
Operating temperature | -10~50 | |||||||||||
Storage temperature | -15~60 | |||||||||||
Noise | ≤55dB | |||||||||||
Elevation | 2000m (More than derating) | |||||||||||
Humidity | 0%~95% ,No condensation | |||||||||||
Dimension and Weight | ||||||||||||
Product Size(L*W*Hmm) | 325*275*102 | 365*297*102 | 390*320*112 | 515*365*117 | 535*462*117 | 630*540*130 | ||||||
Package Size(L*W*Hmm) | 400*330*167 | 440*352*167 | 465*375*187 | 600*430*192 | 615*527*192 | 715*605*205 | ||||||
N.W.(kg) | 6 | 7 | 8.5 | 13 | 15.5 | 23.5 | ||||||
G.W.(kg) | 6.5 | 7.5 | 9.5 | 15 | 17.5 | 25.5 |